What should I do if the central air conditioner is not hot? Analysis of hot issues across the Internet in 10 days
Recently, with the onset of the cold wave, the poor heating effect of central air conditioners has become a hot topic across the Internet. This article combines the entire network search data and repair cases in the past 10 days to systematically analyze the causes and provide solutions for you.
1. Statistics of hot spots across the entire network (last 10 days)

| keywords | peak search volume | Main areas of concern |
|---|---|---|
| Central air conditioner does not heat | 125,000 times/day | North China, East China |
| Air conditioner outlet temperature is low | 87,000 times/day | Yangtze River Basin |
| Air conditioner defrost failure | 62,000 times/day | Northeastern region |
| Filter cleaning cycle | 49,000 times/day | Nationwide |
2. Common problems and solutions
1. The air outlet temperature is not up to standard.
• Normal standard: In heating mode, the air outlet temperature should be more than 15°C higher than the room temperature.
• Solution:
- Check whether the set temperature is lower than 20℃
- Measure the actual outlet air temperature (it is recommended to use an infrared thermometer)
| Fault phenomenon | Possible reasons | Solutions |
|---|---|---|
| Outlet air temperature<30℃ | Insufficient refrigerant | Contact after-sales fluoride supplement |
| Large temperature fluctuations | Defrost program abnormality | Reset control system |
| Not hot locally | Air valve failure | Repair duct system |
2. Frequent defrost problem
• Common phenomenon in winter: defrosting 1-2 times per hour is normal.
• Abnormal behavior:
- Defrost cycle <30 minutes
- Single defrost time>15 minutes
3. Filter clogging problem
• Data from the entire network shows: 87% of users fail to clean the filter on time
• Cleaning recommendations:
- Cleaning once a month in winter
- Pet families need to increase frequency
3. Professional maintenance suggestions
1.Emergency steps:
• Restart the control system after power outage
• Check remote control battery level
• Make sure the mode is set to "Heating" and not "Auto"
2.Self-check list before reporting for repair:
| Check items | normal standard | Tool method |
|---|---|---|
| Supply voltage | 220V±10% | Multimeter test |
| Outdoor unit status | Fan operates normally | visual observation |
| Frost on pipes | Only slight frosting locally | Flashlight inspection |
4. Preventive maintenance guide
•Seasonal maintenance:
- Professional cleaning before winter
- Check refrigerant pressure
- Test the electric heating function
•Daily precautions:
- Avoid frequent power on and off
- Keep doors and windows closed
- Set the temperature reasonably (20-24℃ recommended)
5. Consumers’ key concerns
According to the analysis of complaint data in the past 10 days:
1. Maintenance response speed (38%)
2. Fee transparency (accounting for 29%)
3. Timeliness of parts supply (accounting for 22%)
It is recommended to choose a manufacturer-authorized service provider and be required to produce:
• Service qualification certificate
• Standard price list
• Certificate of original parts
Through the above system analysis and solutions, we hope to help you quickly solve the problem of poor central air conditioning heating. If the problem is still not resolved, it is recommended to contact professional after-sales personnel in time.
check the details
check the details